[<<Previous Entry]
[^^Up^^]
[Next Entry>>]
[Menu]
[About The Guide]
INT 1Ah, 0Ah (10) Read System-Timer Day Counter some XTs
Returns the number of days since January 1, 1980 from the System
Timer.
On entry: AH 0Ah
Returns: CF Set if error; else cleared
CX Number of days since January 1, 1980
--------------------------------------------------------------------------
Notes: The system timer is the timer set when the system is
started. This date is temporary, lasting only as
long as the system is turned on.
This service is available only for XTs dated 1/10/86
and later. ATs and XT-286s will set the Carry Flag,
thus reporting an error state. Previous machines
will report unpredictable results (including the
state of the Carry Flag).
See Also:
INT 1Ah, 04h
INT 1Ah, 0Bh
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.
Written by Dave Pearson